(4 Pack) UL Listed 1/2 NPT Fire Sprinkler Head 155°F (68°C) Pendent Spray K=5.6 K80 Standard Response for Automatic Fire Sprinkler System Pendent Bronze

(4 Pack) UL Listed 1/2 NPT Fire Sprinkler

Technical Details: Temperature Rating: 155°F (68°C) Discharge Coefficient: K=5.6(U.S) /80(Metric) Nominal Orifice Size:1/2"(15mm) Maximum Working Pressure:175psi(12bar) Min. Operating Pressure: 7psi (0.48bar) Factory Hydrostatic Test: 100%@ 500psi (34.5bar) Physical Characteristics Frame: Bronze Button: Brass/Copper Sealing Assembly: Beryllium Nickel w/Teflon Bulb: Glass Compression Screw: Bronze Deflector: Copper

  • Color: Bronze
  • Brand: Tuna
  • ASIN: B075DFSZBY
  • UPC: 717850029586

Ankong®Standard Upright Fire Sprinkler Head 1/2NPT 68 Centigrade (The spray)

Ankong®Standard Upright Fire Sprinkler Head 1/2NPT 68 Centigrade

Fire sprinklers can provide an immediate action against the growing threat of fire in your home. Automatic fire sprnklers will provide a quick response to a fire. A fire sprinkler is the part of a fire sprinkler system that discharger water when the effects of a fire have been detected. It can replace your old or damaged fire sprinkler head.

  • Color: The spray
  • Brand: Ankong
  • ASIN: B01EV10XQO
  • UPC: 601783006328

(6 Pack) 1/2" IPS Fire Sprinkler Head Semi-Recessed Escutcheon Two Piece Cover Ring Chrome Plated

(6 Pack) 1/2" IPS Fire Sprinkler Head Semi-Recessed

Recessed two piece push fit rosette suitable for most 1/2"NPT pendent sprinkler head. Maximum adjustment depth 20mm.Two piece Rosettes must be installed in accordance with relevant guidelines issued by the Authority Having Jurisdiction.The above price is only for escutcheon.

  • Brand: Happy Tree
  • ASIN: B01MT8DV4L
  • UPC: 717850027476

UL Listed 1/2"NPT Fire Sprinkler Head 155°F (68°C) K=5.6 Concealed Pendent Spray K80 Standard Response for Automatic Fire sprinkler System Dia 5mm Bulb Concealed Head with White Cover Plate

UL Listed 1/2"NPT Fire Sprinkler Head 155°F (68°C)

Technical Details: Temperature Rating: 155°F (68°C) Discharge Coefficient: K=5.6(U.S) /80(Metric) Nominal Orifice Size:1/2"(15mm) Maximum Working Pressure:175psi(12bar) Min. Operating Pressure: 7psi (0.48bar) Factory Hydrostatic Test: 100%@ 500psi (34.5bar) Physical Characteristics Frame: Bronze Button: Brass/Copper Sealing Assembly: Beryllium Nickel w/Teflon Bulb: Glass Compression Screw: Bronze Deflector: Copper

  • Brand: Tuna
  • ASIN: B076NXWWXZ
  • UPC: 717850029869

QUICKSTOP Q-COM Talon Fire Sprinkler Head Tool, 1/2" to 3/4"

QUICKSTOP Q-COM Talon Fire Sprinkler Head Tool, 1/2"

The Quickstop Talon is the ONLY sprinkler tool on the market that stops 1/2" and 3/4" sprinkler heads whether they are intact, damaged or completely sheared. Each Talon tool is designed to release when heated. This feature allows the tool to function as a temporary sprinkler head if a second fire were to start. The Talon is engineered to align itself to the sprinkler head making it the easiest sprinkler tool to use. It has a heavy duty, single hand operated design and is completely reusable. The Quickstop Talon has been tested to hold 100% water tight up to 350 PSI or 2400 KPA.

  • Color: Chrome
  • Brand: QUICKSTOP
  • ASIN: B00LZQVXGS
  • UPC: 025188072304

Happy Tree FSHW01 Fire Sprinkler Head Wrench Spanner for 1/2 Recessed/Concealed Sprinkler Head

Happy Tree FSHW01 Fire Sprinkler Head Wrench Spanner

This wrench could be for recessed/concealed fire sprinkler Head in 1/2" 15mm. Size:230mmx70mm. The above price is only for 1pc of wrench FSHW01.

  • Brand: Happy Tree
  • ASIN: B01NCSLM8W
  • UPC: 717850026646

FSHW04 Fire Sprinkler Head Wrench Spanner for 1/2 Exposed/Semi - Recessed/Concealed Sprinkler Head

FSHW04 Fire Sprinkler Head Wrench Spanner for 1/2

This wrench could be for 1/2" exporsed or recessed or concealed sprinkler Head. Length:appr.200mm; Weight: appr.180g.

  • Brand: Happy Tree
  • ASIN: B01MR2LNS7
  • UPC: 717850026684

(2 Pack) White Fire Sprinkler Head Guard for Both 1/2" & 3/4" Sprinkler Head for Protecting Flush Mount & Side Wall & Semi - Recessed Sprinkler Head

(2 Pack) White Fire Sprinkler Head Guard for

Excellent sprinkler protector for Flush Mount & Horizontal & Pendent Head,suitable for both 1/2" and 3/4" Fire Head, strong protection.Welded at all points for strength, easy installation of sprinkler head protector. Please kindly noted the price is only for the guard.

  • Color: 2 Pack White
  • Brand: Happy Tree
  • ASIN: B076KTW3LT
  • UPC: 717850029852

Tuna (4 Pack) UL Listed 1/2 NPT Fire Sprinkler Head 155°F (68°C) K=5.6 Pendent Spray K80 Standard Response for Automatic Fire sprinkler System Pendent Chrome

Tuna (4 Pack) UL Listed 1/2 NPT Fire

Technical Details: Temperature Rating: 155°F (68°C) Discharge Coefficient: K=5.6(U.S) /80(Metric) Nominal Orifice Size:1/2"(15mm) Maximum Working Pressure:175psi(12bar) Min. Operating Pressure: 7psi (0.48bar) Factory Hydrostatic Test: 100%@ 500psi (34.5bar) Physical Characteristics Frame: Bronze Button: Brass/Copper Sealing Assembly: Beryllium Nickel w/Teflon Bulb: Glass Compression Screw: Bronze Deflector: Copper

  • Color: Chrome
  • Brand: Tuna
  • ASIN: B075D97BWV
  • UPC: 717850029579

QUICKSTOP Q-MT Fire Sprinkler Head Tool

QUICKSTOP Q-MT Fire Sprinkler Head

The Quickstop Multi-Tool is the FIRST AND ONLY fire sprinkler multi-tool on the market. It gives firefighters the equipment they need to attack commercial and high-rise fires and it stops fire sprinklers. The tool can be used to remove FDC caps, make standpipe connections, shut off residential utilities, adjust system pressures (PRV), open oxygen cylinders, blocks doors open, and stop fire sprinklers. Attaching a multi-tool to your high-rise hose packs gives your firefighters the equipment they need on the fire floor when they need it most. Quickly stopping the water at the head, allows the remaining fire protection system in the building to operate while crews check for extension of fire or search for main the water shut off. The Quickstop Multi-Tool also reduces building damage which results in less clean up for fire crews and shorter on scene times. The Talon and Multi-Tool are the only sprinkler tools that stop 1/2" and 3/4" heads whether they are intact, damaged or completely sheared. Tested up to 350 PSI.

  • Brand: QUICKSTOP
  • ASIN: B00LZQW6GO
  • UPC: 696735293543
Similar Fire Sprinkler Results
Fire Sprinkler Video Reviews

How do FIRE SPRINKLERS Work? (slomo)

Fire Sprinkler

This shows how fire sprinklers work and just how sensitive and fast they operate when heated up. ...

Tags: slow motion,how to,slomo,fire,protection,nfpa,t...

How Do Fire Sprinklers Know There's A Fire?

Fire Sprinkler

There's a big fire in the building and suddenly all the sprinklers turn on -- that's not really h...

Tags: current events,Science,fire,fire sprinklers,Fir...

Electrical Fire Caught on Surveillance Video with Fire Sprinkler Activation

Fire Sprinkler

Tags: